Geo Acoustics – GeoPulse 2

The GeoPulse 2 is a significant upgrade for the industry-proven GeoPulse and GeoPulse + systems which are renowned for their reliability, ruggedness, ease of operation and flexibility.


The GeoPulse 2 deck unit is a drop-in replacement for the original GeoPulse transmitter (5430P) using the same deck cable and connector and also replaces the need for the separate GeoPulse Receiver (5210A). It offers a range of programmable source signatures including CW, Chirp and Ricker and output power is continuously adjustable up to 10 kW.
The complete sub-bottom profiling system comprises of the GeoPulse 2 transceiver which is connected to either 4, 9 or 16 T135 transducers. 4 transducer arrangements can either be hull mounted or in an over-the-side mount assembly (Model 132). Hull mounting is used for 9 and 16
transducer configurations.

KEY FEATURES
Frequency range 1.5-18 kHz
Output power up to 10 kW
Resolution 6 cm
Penetration up to 80 m
Over-the-side or hull mounted
Third party software integration
APPLICATIONS
Pipeline detection
Geological surveys
Dredging surveys
Environmental surveys
Buried object detection

DECK UNIT
Mechanical :Aluminium case
Dimensions :Dimensions: 430 mm (W) x 440 mm (D) x 180 mm (H)
ENVIRONMENT
0 °C – 40 °C, -20 °C – 75 °C (storage)
< 95 % RH, non-condensing (operation)
CONNECTORS
Power in, deck cable (up to 50m), 3 x Serial | PPS input, external trigger input
Indicators : Power on, HV, Time sync, Sonar Active, Cable Fault
POWER
Power :Power Input: 200-240 V AC, 20A, 50/60 Hz
SERIAL
Serial :3 x RS232 with overvoltage protection | Range of baud rates selectable
PPS: TTL level, protected, edge selectable
ACQUISITION SOFTWARE
Type:  SonarWiz fully featured SBP with control interface (locked for use with GeoPulse 2
Features:  Control of all system parameters | Full range of processing tools | Data export in industry standard formats | 1 year of maintenance included

TRANSDUCER
Output Power 10 kW peak (adjustable as % of full scale)
WAVEFORMS
Pinger: Frequency & cycles select: 1 – 32 cycles (1 cycle steps). 1.5 – 18 kHz (0.1 kHz steps)
Ricker: Spread spectrum (by highest frequency component). 4kHz – 15 kHz (0.1 kHz steps)
Chirp: Range of sweeps available with 5, 10 or 15 kHz bandwidth, 8, 16 or 32 ms length, using frequencies between 1.5 kHz – 18 kHz
PERFORMANCE
Rep Rate Up to 20 PPS (waveform dependent)
Source Level 217 dB ±3 dB re 1 μPa @ 1 m (4 transducers) | 221 dB ±3 dB re 1 μPa @ 1 m (9 transducers) | 224 dB ±3 dB re 1 μPa @ 1 m (16 transducers)
Beamwidth 55° using 3.5 kHz (combined mode, 4 transducers) | 40° using 3.5 kHz (combined mode, 9 transducers) | 30° using 3.5 kHz (combined mode, 16 transducers)
RESOLUTION & PENETRATION
Resolution up to 6 cm
Penetration Up to 80 m (fine clay), up to 20 m (sand)
ACQUISITION
Dual channel, 800 kHz front end sampling, 50/100 kHz sample output, 24 bit

OVER-THE-SIDE MOUNT ASSEMBLY (MODEL 132B)
Physical Dimensions: 700 mm (L) x 520 mm (W) x 460 mm (H) | Weight 120 kg
MOUNTING POLE
One section: 1830 mm
Two sections: 3600 mm
Three sections: 5370 mm
TRANSDUCER ARRAYS